Fluke Digital Multimeter 15B+ 17B+ 18B+ Current Voltage Frequency Temperature Tester. FLUKE 15B+/17B+/18B+ high precision temperature frequency auto multifunction digital multimeter for Mobile Phone repair.
Option:
1. Fluke 15B+ Digital Multimeter.
2. Fluke 17B+ Digital Multimeter.
3. Fluke 18B+ Digital Multimeter.
4. Fluke 101 Digital Multimeter.
5. Fluke 15B MAX 02 (with super-pointed pen)
6. Fluke 17B MAX 02 (with super-pointed pen)
Fluke 17B MAX Inherits and continues the classic design of 17B+, with further improved functions: Input Alert Alarm, Simple interface to wake meter
from sleep mode by activating any buttons, test leads with fine probes to help electricians and electronic R&D personnel make accurate measurements.
Fluke 15B MAX Inherits and continues the classic design of 15B+, with further improved functions: Input Alert Alarm, Simple interface to wake meter
from sleep mode by activating any buttons, test leads with fine probes to help electricians and electronic R&D personnel make accurate measurements.
Product Features:
- Faster response
- Greater capacitance range: 0.01nF ~ 1000μF
- The brighter: Add white LED backlight
- Larger screen: Larger than the original 1.5 times
Product Specification:
- Maximum Voltage between any Terminal and Earth Ground: 1000 V
- Display(LCD): 4000 counts, updates 3/sec
- Battery Type: 2 AA,NEDA 15A, IEC LR6
- Battery life: 500 hours minimum(50 hours in LED Test mode without load. The hours with load depends on the type - of LED under test)
- Operating Temperature: 0 deg to 40 deg
- Storage Temperature: -30 deg to 60 deg
- Operating Humidity: Non-condensing≤90%at 10deg to 30deg;≤75% at 30deg to 40deg
- Operating Humidity,40MC Range: ≤80% at 10deg to 30deg;≤70% at 30deg to 40deg
- Operating Altitude: 2000m
- Storage Altitude: 12.000m
- Temperature Coefficient: 0.1×(specified accuracy)/deg(<18deg or > 28deg)
- Fuse protection for current inputs: 440 mA,1000 V Fast Fuse, Fluck specified part only.
- 11A,1000v Fast Fuse, Fluke specified part only.
- Size(H×W×L): 183×91×49.5(mm)
- IP Rating: .IP 40
- Safety: .IEC 61010-1, IEC61010-2-030 600V CAT â
¢,1000V CATâ
¡ï¼Pollution Degree 2
- Electromagnetic Environment: IEC 61326-1:Portable
- Class A Equipment(Industrial Broadcasting and Communication Equipment)
Function Range Accuracy:
- AC Volts: 400mV / 4V / 40V / 400V / 1000V, +/-3.0+3, 0.1Mv to 1,000V
- DC Volts: 400mV / 4V / 40V / 400V / 1000V, +/-1.0+10, 0.1Mv to 1,000V
- AC Current: 400uA / 4000uA / 40mA / 400mA / 4A / 10A, +/-1.5%+3 ,0.1UA to 10A
- DC Current: 400uA / 4000uA / 40mA / 400mA / 4A / 10A, +/-1.5%+3 ,0.1UA to 10A
- Capacitance: 50nF/ 200Nf / 2Uf / 20Uf / 200Uf / 20Mf ,+/-2%+5, 0.01nF to 100uF
- Resistance: 400 / 4K / 40K / 400K / 4M / 40M Ohm, +/-0.5%+3, 0.1 ohm to 40Mohm
RANGE VOLTS AC 0.1Mv to 1,000V
RANGE VOLTS DC 0.1Mv to 1,000V
RANGE AC CURRENT 0.1UA to 10A
RANGE DC CURRENT 0.1UA to 10A
RANGE RESISTANCE 0.1 ohm to 40Mohm
RANGE CAPACITANCE 0.01nF to 100uF
VOLTAGE AC 400mV / 4V / 40V / 400V / 1000V, +/-3.0+3
VOLTAGE DC 400mV / 4V / 40V / 400V / 1000V, +/-1.0+10
RESISTANCE 400 / 4K / 40K / 400K / 4M / 40M Ohm, +/-0.5%+3
CAPACITY 50nF/ 200Nf / 2Uf / 20Uf / 200Uf / 20Mf ,+/-2%+5
CURRENT AC 400uA / 4000uA / 40mA / 400mA / 4A / 10A, +/-1.5%+3
CURRENT DC 400uA / 4000uA / 40mA / 400mA / 4A / 10A, +/-1.5%+3
Package List :
- 1pcs x Original Fluke digital multimeter
- 2pcs x Test lead lines
-
1pcs x User Manual